0 0.02 0.04 0.06 0.08 0.1 0.12 0.14 0.16 0.18 .2 0 10 20 30 40 50 60 70 Angle of Incidence [deg] HySPAR Measurement (4 sec) HySPAR Measurement (10 sec) Calculation -  .02 -0.015 -0.01 -0.005 0 0.005 0.01 0.015 . 0 10 20 30 40 50 60 70 Angle of Incidence [degrees] 4 sec. integration 10 sec. integration Stokes Inversion Validation •    Degree of Linear Polarization (DoLP) •    Initial DoLP validation using tilted dielectric plate (Pyrex). •    Refractive index and thus Fresnel transmittance are well known. •    Measurement made at center of field. •    Center wavelength: 500 nm 0.20 0.02 -0.02 Achieving 0.5-1% polarimetric accuracy in this case To PSIM Page Next Page